Specifications of the manual RF shield box
*Customizable to actual needs.
NO.
| Model | Isolation(dB) | Size(mm) | Frequency(GHz) | Interface type |
1
| HBTE-SB-MNNN-6-50-40375 | ≥70 | 270L*250W*160H | 0.1-6 | 6*SMA(f)-SMA(f) 1*Fiber optic Waveguide(bore size 30mm) 2*USB2.0 |
2 | HBTE-SB-MNNN-6-70-40413 | ≥70 | 460L*400W*275H | 0.1-6 | 6*SMA(f)-SMA(f) 4*USB2.0 1* RJ45 Ethernet 10/100/1000 1*AC 110V-240V 10A |
3 | HBTE-SB-MNNF-6-70-41474-C | >=70 | 480L*420W*440H | 0.1-6 | 8*SMA(f)-SMA(f) 4*USB3.0 4*RJ45Ethernet 10/100/1000 |
4 | HBTE-SB-MNNN-6-70-404115 | >=70 | 420L*420W*450H | 0.1-6 | 16*SMA(f)-SMA(f) 4*USB3.0 4*RJ45Ethernet 10/100/1000 1*AC 250V 10A |
5 | HBTE-SC-MNNF-6-70-1001063 | >=70 | 1000L*720W*370H | 0.8-6 | 8*N(f)-SMA(f) 4*USB3.0 4* RJ45 Ethernet 10/100/1000M 1*DB9 AC 110V-240V 10A |
6 | HBTE-SC-MNNF-6-70-1201161 | >=70 | 905L*1200W*1800H | 0.1-6 | 20*SMA(f)-SMA(f) 7*RJ45 Ethernet 10/100/1000 2* RJ45 Ethernet 10G 3*DB9 1*AC220V 10A |
7 | HBTE-SB-MNNF-6-70-414212 | >=70 | 465L*450W*174H
| 0.1-6 | 12*SMA(f)-SMA(f) 6*USB2.0 2*RJ45 Ethernet 10/100/10000 1*AC 220V 10A |
Features of the manual RF shield cabinet
Stable isolation;
Multiple I/O connections;
Custom size and configuration;
Regular product inspection services;
Continuous cost optimization and design optimization to provide customers with the best investment cost performance;
A company team that continues to innovate and is reluctant to progress is the fundamental guarantee for product upgrades and customer confidence.
Applications of the manual RF shielding box
A manual shield box can be used for base station testing of CDMA, EVDO, GSM, UMTS, HSPA, LTE, WIMAX signals Test, UE test, EMI test, coupling test, Bluetooth tests and WIFI test, etc.
Electrical Interfaces of the RF shielded test box
RJ45 interface: connect the external network cable with the internal network cable equipment to shield and shield signal interference and leakage;
DC power connector: connect the equipment at both ends of the box inside and outside to shield signal interference and leakage;
USB filter: connect the devices inside and outside the box for data transmission and shield signal interference and leakage;
Waveguide: can penetrate the cable and shield signal interference and leakage;
Power supply filter; used for importing power from the outside of the box to the inside of the box, shielding and shielding signal interference and leakage;
DB9 interface: connect the external equipment of the box and the internal equipment to shield and shield signal interference and leakage;
SMA, N, 2.92 connectors: used to transmit signals from the outside of the box to the inside of the line body without interference from other signals. Similarly, internal signals can also be transmitted to the outside through the connector to shield and shield signal interference and leakage.